Status
code
Description according to Pro-
bus standard
Possible cause
0 x 89 good (non-cascade) - active ad-
visory alarm - low limited
Lo-Alarm
0 x 8a good (non-cascade) - active ad-
visory alarm - high limited
Hi-Alarm
0 x 8d good (non-cascade) - active crit-
ical alarm - low limited
Lo-Lo-Alarm
0 x 8e good (non-cascade) - active crit-
ical alarm - high limited
Hi-Hi-Alarm
88 Dierential pressure transmitter DPT10 - metal measuring diaphragm Probus PA
11 Supplement