Display
5 6 7 8
4
1
Fig. 10: Wiring plan external indicating and adjustment unit for PA/FF sensors
1 To the sensor
Connection via confectioned cable with 5-pole socket M12 x 1
The connection between the external indicating and adjustment unit
and sensor with 5-pole plug M12 x 1 is carried out according to the
following chart. The specication of the wire colours refers to the
confectioned special cable supplied with this sensor version.
3)
Wire colour External indicating and adjustment
unit
Black Terminal 5
White Terminal 6
Blue Terminal 7
Brown Terminal 8
3)
Plug M12 x 1, optional with single and double chamber housing.
Wiring plan (PA/FF sen-
sors)
External indicating and adjustment unit 17
5 Connecting to power supply
31550-EN-100726
Vedere la pagina 16